BMBB91 KEKA 090009 STQEKA A SPOT FORECAST REQUEST HAS JUST BEEN RECEIVED FOR A PRESCRIBED FIRE NAMED "Mad Ridge Fuelbreak Unit 6C" PRIORITY: IMMEDIATE DATE: 12/9/09 TIME: 1000 PROJECT NAME: Mad Ridge Fuelbreak Unit 6C PROJECT TYPE: PRESCRIBED REQUESTING AGENCY: Six Rivers NF-Mad River RD REQUESTING OFFICIAL: John Busscher REQUEST REASON: IAMS FAX: (707) 574-6273 EMERGENCY PHONE: (707) 574-6233 LOCATION: T3S R8E SEC33-32 STATE: CA DLAT: 33.86954 DLON: 116.15067 EXPOSURE: All FUEL TYPE: Conifer/Hardwood Hand piles SHELTERING: PARTIAL BOTTOM ELEVATION: 3400 TOP ELEVATION: 4320 SIZE (ACRES): 20 WEATHER CONDITIONS AT PROJECT OR FROM NEARBY STATIONS Valley ELEV=2732 TIME=1312 WIND=0,G to 6 T=38 TW= RH=34 TD= clear Valley ELEV=2732 TIME=1512 WIND=0, G to 4 T=37 TW= RH=34 TD= clear ELEV= TIME= WIND= T= TW= RH= TD= ELEV= TIME= WIND= T= TW= RH= TD= ...REMARKS... Weather Taken from Ruth Raws ...WEATHER PARAMETERS REQUESTED... CLOUDS / WEATHER: 0,0,1 TEMPERATURE: 0,0,1 RELATIVE HUMIDITY: 0,0,1 EYE LEVEL WIND: 0,0,1 SURROUNDING RIDGE WIND: 0,0,1 SMOKE DISPERSION: 0,0,1 SITE: EKA OFILE: 20091209.MADRI.01 TIMEZONE: PST8PDT